Instrument Database:

Applied Biosystems - API 2000 LC/MS/MS System



Year of introduction
Statusavailable
CompanyApplied Biosystems
CategoriesHyphenated Techniques: LC-MS
Mass spectrometer: ESI-MS
Mass spectrometer: LC-MS
The API 2000™ LC/MS/MS System brings the power and performance of triple quadrupole mass spectrometry to your benchtop.

The API 2000™ LC/MS/MS System brings the power and performance of triple quadrupole mass spectrometry to your benchtop.
  • Streamlined design results in a true benchtop LC/MS/MS system -- requiring less space in your lab
  • TurboIonSpray® and APCI sources with fully integrated gas and electrical connections allow quick and easy changes of ionization modes
  • Robust ion sources and proven Curtain Gas™ interface technology ensure trouble-free operation and productivity
Revolutionary LINAC™ collision cell technology provides fast scan times without compromising sensitivity or mass spectral quality for superior MS/MS performance
Windows NT® platform-based Analyst™ software provides single point control of LC, built-in syringe pump, and diverter valve, expediting methods development in drug discovery and development.
Information Dependent Acquisition (IDA) enables unattended, automated MS to MS/MS acquisition providing better structural information

Maximum Flexibility
A compact, easy-to-use LC/MS/MS system for demanding, high-throughput MS/MS laboratories, this innovative system features patented Applied Biosystems/MDS SCIEX API technology within easily changeable ion sources, providing maximum flexibility for use in a wide range of applications.

Ideal for High Throughput
Analyst™ Software provides data processing and total instrument control of data acquisition, including the built-in syringe pump and diverter valve, for the API 2000 system. Sophisticated software applications such as Information Dependent Acquisition (IDA) and Metabolite ID provide automated metabolite profiling on in vivo and in vitro samples. Automaton, an application for automated compound optimization, method development, and quantitative analysis, further expands the range of solutions provided by the API 2000™ system. The single-point control, proven reliability, revolutionary LINAC® collision cell, and advanced Analyst™ Software applications make the API 2000™ system the ideal solution for high throughput quantitative and qualitative challenges.
Specifications
Computer Requirements (PC)

Operating System   
Windows 2000/XP
CD-ROM     CVC RW (CD RW capable)
Memory     1 GB RAM
CPU     3.2 GHz
Hard Disk 200GB
Display 19" Viewable Color monitor recommended

Performance/Throughput

Dynamic Range     1cps to 4x106 cps (pulse counting)
Scan speed     up to 2400 amu/sec
Mass Range     m/z 5-1,800

System Setup Specifications

Gas Supplies     50 psi UHP nitrogen, 100 psi zero air, 50 psi filtered, dry air

Physical Specifications

Width     104 cm (41 in)
Depth     50 cm (20 in)
Weight     111 kg (244 lb)
Height     64 cm (25 in)

Power Requirements

Voltage 2 separate 207 V minimum to 242 V maximum
Circuit Current 15 A grounded single phase circuit

Leave a Reply

Subscribe to Posts | Subscribe to Comments

About Me

My photo
gandhinagar, gujarat, India
HPLC LOVER

Labels

MY PHOTOS ON FACE BOOK

MY OLDER BLOGS

MY FACE BOOK PROFILE

KAUSHIK ZALA, HPLC SCIENTIST. Powered by Blogger.
Copyright © 2013 Yours Chromatographically, Kaushik Zala | Dark Simple Blogger Template Powered by Blogger | Created by Renadel Dapize | Ori. BRS-bt Djogzs | All Rights Reserved